Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Nonlinear Load and RLC Pulse Shaping Surge Generator Models in Simulation Environment

Tytuł:
Nonlinear Load and RLC Pulse Shaping Surge Generator Models in Simulation Environment
Autorzy:
Edirisinghe, M.
Tematy:
Nonlinear load
surge generator
surge protection
loading effect
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Język:
angielski
Prawa:
CC BY: Creative Commons Uznanie autorstwa 4.0
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 17, 3; 334-347
2299-3843
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
The present study was performed in order to understand how a nonlinear load affects the characteristics of the RLC pulse shaping surge generator waveforms under simulation studies. The obtained results were compared when analytical equations were used as source models for both 1.2/50 s voltage & 8/20 s current impulses. Three circuit models; Capacitor Bank generator, Combination waveform generator and Schaffner generator were evaluated under nonlinear loads varied from 10Ω to 106 Ω for voltage impulses and for current impulses it was from 10-4 Ω to 1 Ω. As it can perceive from the analysis, delay time, rise time and FWHM remain unchanged throughout the tested impedance range when used model equations as generator sources. It was found that for voltage impulses, these values were 4.95 μs, 1.20 μs and 81.8 μs respectively. For current impulses, these values were 16.2 μs, 8.02 μs and 20.7 μs respectively. However results obtained for generator circuit models shows that delay time, rise time and FWHM deviated from above values up to maximum of 35.15 %, 106.67 % & 115.16 % respectively for voltage impulses. For current impulses these deviations were up to maximum of 79.63 %, 48.75 % & 39.61 % respectively. The deviations were due to influence caused by the nonlinear load to the generator circuit parameters and effective internal impedance.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies