Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Modelling study of flue gas flow pattern with pressure, amount and shape variation catalytic converter

Tytuł:
Modelling study of flue gas flow pattern with pressure, amount and shape variation catalytic converter
Autorzy:
Ghofur, A.
Isworo, H.
Subagyo, R.
Tamjidillah, M.
Siswanto, R.
Ma’ruf, -
Purwanto, H.
Muchsin, -
Tematy:
shape effect
absorption effectiveness
ANSYS
catalytic converter
filter-not- cut
filter-cut
efekt kształtu
skuteczność wchłaniania
katalizator
Data publikacji:
2020
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Język:
angielski
Prawa:
Wszystkie prawa zastrzeżone. Swoboda użytkownika ograniczona do ustawowego zakresu dozwolonego użytku
Źródło:
Archives of Materials Science and Engineering; 2020, 103, 1; 5--17
1897-2764
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Purpose: The purpose of this study is to analyse the modelling of exhaust gas flow patterns with variations in pressure, number, and shape of filters on the catalytic converter. Design/methodology/approach: The research method used is a simulation using ANSYS, which starts by creating a converter catalytic model with pressure variations: (0.5-1.5 atm), number of filters: (2-5), and the form of filter-cut/filter-not-cut. Findings: The decrease in velocity is caused by non-uniform velocity in the exhaust gas flow that occurs when passing through a bend in the filter-cut that serves as a directional flow to create turbulence. Filter-cut type tends to have fluctuating pressure, turbulence flow pattern shape so that contact between filter and exhaust gas is more effective. Based on the analysis of flow patterns, the speed and pressure of the 5 filter-not-cut design at a pressure of 0.5 are the best, while at pressure (1-1.5 atm) the type 5 filter-cut is the best. Research limitations/implications: This study is limited to filter-not-cut and filter-cut types with variations in the number of filters: 2, 3, 4, and 5, and the inlet pressure between 0.5-1 atm. Practical implications: The practical implications of this study are to find a catalytic converter design that has advantages in the effectiveness of exhaust gas absorption. Originality/value: The results show that the filter-not-cut and filter-cut types have the best effectiveness in the number of 5 filters. Filter-not-cut at the pressure of 0.5 atm and filter-cut at pressure (1-1.5 atm).

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies