Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Configuration of the parameters for scanner-based track detector evaluation system

Tytuł:
Configuration of the parameters for scanner-based track detector evaluation system
Autorzy:
Csordás, Anita
Tóth-Bodrogi, Edit
Kovács, Tibor
Tematy:
background track density
CR-39
etching conditions
indoor radon
sensitivity for radon
Data publikacji:
2020
Wydawca:
Instytut Chemii i Techniki Jądrowej
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 PL
Źródło:
Nukleonika; 2020, 65, 2; 133-137
0029-5922
1508-5791
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
According to the new European Union Basic Safety Standards (EU-BSS), preparation of the National Radon Action Plan is obligatory for the Member States. One of the plan’s aims is to carry out an indoor radon survey to identify radon-prone areas. In the radon surveys, track detector methods are used. At the University of Pannonia (Veszprém, Hungary), a new scanner-based detector evaluation system has been developed. For the application of the new system, the selection of appropriate parameters is necessary. In this study, selection of the applied track detectors and setting of the etching conditions have been carried out. Two different types of allyl diglycol carbonate (ADC or CR-39) track detectors were investigated, taking into account the detector’s background and response during the exposure (determination of calibration factor). The Baryotrak’s background track density (0–1.5 tracksmm–2) was lower than that of the 0.8–4 tracksmm–2. The response of the Tastrak was higher, but the deviation of the calibration factor was much higher (1.2–5.3 × 10–3 tracksmm–2/(Bqdaym–3)) than in the case of the Baryotrak (1.4–2.8 × 10–3 tracksmm–2/(Bqdaym–3)). After the systematic review of the etching system, a new method was developed. For the determination of the optimal track diameter, the argon fluoride (ArF) laser was applied to create tracks with diameters in the range of 10–100 µ. The optimum track size was in the range of 40–60 µ. On this basis, new etching conditions were determined: 6.25 M NaOH solution, a temperature of 90 degree centigrade, and time period of 8 hours.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies