Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Measurement of liquid holdup and axial dispersion in trickle bed reactors using radiotracer technique

Tytuł:
Measurement of liquid holdup and axial dispersion in trickle bed reactors using radiotracer technique
Autorzy:
Pant, H.
Saroha, A.
Nigam, K.
Tematy:
axial dispersion model
holdup
mean residence time
Peclet number
residence time distribution
trickle-bed reactor
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Język:
angielski
Prawa:
Wszystkie prawa zastrzeżone. Swoboda użytkownika ograniczona do ustawowego zakresu dozwolonego użytku
Źródło:
Nukleonika; 2000, 45, 4; 235-241
0029-5922
1508-5791
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
The holdup and axial dispersion of aqueous phase has been measured in trickle bed reactors as a function of liquid and gas flow rates using radioisotope tracer technique. Experiments were carried out in a glass column of inner diameter 15.2´10-2 m column for air-water system using three different types of packings i.e. non-porous glass beads, porous catalysts of tablet and extrudate shape. The range of liquid and gas flow rates used were 8.3´10-5-3.3´10-4 m3/s and 0-6.67´10-4 m3/s, respectively. Residence time distributions of liquid phase were measured and mean residence times were determined. The values of liquid holdup were calculated from the measured mean residence times. It was observed that liquid holdup increased with increase in liquid flow rates and was independent of increase in gas flow rates used in the study. Two-parameter axial dispersion model was used to simulate measured residence time distribution data and values of mean residence time and Peclet number were obtained. It was observed that values of Peclet number increases with increase in liquid flow rate for glass beads and tablets and remains almost constant for extrudates. The values of mean residence time obtained from model simulation were found to be in good agreement with the values measured experimentally.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies