Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Inundation controlling practice in urban area: Case study in residential area of Malang, Indonesia

Tytuł:
Inundation controlling practice in urban area: Case study in residential area of Malang, Indonesia
Autorzy:
Harisuseno, Donny
Bisri, Mohammad
Haji, Tunggul S.
Tematy:
channel normalization
inundation
runoff
SIMODAS model
storage well
urban area
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Język:
angielski
Prawa:
CC BY-NC-ND: Creative Commons Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 PL
Źródło:
Journal of Water and Land Development; 2020, 46; 112-120
1429-7426
2083-4535
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Flood inundation processes in urban areas are primarily affected by artificial factors such as drainage facilities, local alterations of topography and land uses. The objective of this study is to examine the capability of hydrological model SI-MODAS to estimate runoff and investigating the utilization of storage well in controlling runoff in a residential area. The result of the estimated runoff from the hydrological model was compared with the existing capacity of the drainage channel to identify which channel experienced the problem of inundation. The location of inundation was used to determine the location and number of storage well. The results showed that SIMODAS model could be applied in runoff analyses with 8.09% of relative error compared with runoff depth from field measurement. The existing capacity of the channel could not accommodate runoff Q10yr where the inundation discharge was approximately 0.24 m3·s–1 (at outlet point 1) and 0.12 m3·s–1 (at outlet point 2). The inundation problem was overcome by using a combination system between channel normalization (reduce 35% of total inundation discharge) and storage well system (reduce 65% of total inundation discharge). The storage well was designed at 20 locations (at outlet point 1) and 16 locations (at outlet point 2) which each well had a discharge of 0.0058 m3·s–1. The storage well combined with channel normalization could be used as an alternative way to solve inundation problems in a residential area considering the constraint of land space limitation in the urban area.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies